CPU M13C - 16DI / 12 DO / 1AI, 2x RJ45 Modbus TCP/ Ethernet/ Profinet |
(Nettó ár: 146.697 Ft) |
186.305
Ft
|
CPU M13C - 16DI / 12 DO / 1AI, 2x RJ45 Modbus TCP/ Ethernet/ Profinet
M13-CCF0000 - Yaskawa Micro PLC CPU S7
Programozható Simatic manager és TIA Portal-on keresztül.
Kommunikáció
- Profinet
- Modbus RTU / TCP
- OPC UA / WebServer
Termék tudás szintje megfelel: Siemens 1215 - 6ES7215-1HG40-0XB0 (csak 1 Analaóg bemenettel)
Yaskawa - VIPA plc
Yaskawa Mikro moduláris plc
- 10 -100x gyorsabb, mint a hagyományos vezérlések
- Profinet alapkiépítésben
- 64kbyte memória (128kbyte -ig bővíthető)
- SD kártya bővíthetőség
- 16 digit be- / 12 digit kimenet
- Ingyenes SPEED 7 Studio program
- Simatic manger és TIA Portal programozhatóság
- Ethernet PG/OP csatorna
- Max. 7 Watt fogyasztás
- 8 modul bővíthetőség
M13-CCF0000 - CPUs | CPUs STEP7 programmable, C class
Order no. |
M13-CCF0000 |
Type |
CPU M13C |
Module ID |
- |
General information |
|
Note |
- |
Features |
Powered by SPEED7 |
Technical data power supply |
|
Power supply (rated value) |
DC 24 V |
Power supply (permitted range) |
DC 20.4...28.8 V |
Reverse polarity protection |
|
Current consumption (no-load operation) |
120 mA |
Current consumption (rated value) |
360 mA |
Inrush current |
3 A |
I2t |
0.1 A2s |
Max. current drain at backplane bus |
1 A |
Max. current drain load supply |
- |
Power loss |
7 W |
Technical data digital inputs |
|
Number of inputs |
16 |
Cable length, shielded |
1000 m |
Cable length, unshielded |
600 m |
Rated load voltage |
DC 24 V |
Reverse polarity protection of rated load voltage |
|
Current consumption from load voltage L+ (without load) |
25 mA |
Rated value |
DC 24 V |
Input voltage for signal "0" |
DC 0...5 V |
Input voltage for signal "1" |
DC 15...28.8 V |
Input voltage hysteresis |
- |
Signal logic input |
Sinking input |
Frequency range |
- |
Input resistance |
- |
Input current for signal "1" |
3 mA |
Connection of Two-Wire-BEROs possible |
|
Max. permissible BERO quiescent current |
0.5 mA |
Input delay of "0" to "1" |
3 µs – 15 ms / 0.5 ms – 15 ms |
Input delay of "1" to "0" |
3 µs – 15 ms / 0.5 ms – 15 ms |
Number of simultaneously utilizable inputs horizontal configuration |
16 |
Number of simultaneously utilizable inputs vertical configuration |
16 |
Input characteristic curve |
IEC 61131-2, type 1 |
Initial data size |
16 Bit |
Technical data digital outputs |
|
Number of outputs |
12 |
Cable length, shielded |
1000 m |
Cable length, unshielded |
600 m |
Rated load voltage |
DC 24 V |
Reverse polarity protection of rated load voltage |
|
Current consumption from load voltage L+ (without load) |
20 mA |
Total current per group, horizontal configuration, 40°C |
6 A |
Total current per group, horizontal configuration, 60°C |
6 A |
Total current per group, vertical configuration |
6 A |
Output voltage signal "1" at min. current |
L+ (-0.8 V) |
Output voltage signal "1" at max. current |
L+ (-0.8 V) |
Output current at signal "1", rated value |
0.5 A |
Signal logic output |
Sourcing output |
Output current, permitted range to 40°C |
5 mA to 0.6 A |
Output current, permitted range to 60°C |
5 mA to 0.6 A |
Output current at signal "0" max. (residual current) |
0.5 mA |
Output delay of "0" to "1" |
2 µs / 30 µs |
Output delay of "1" to "0" |
3 µs / 175 µs |
Minimum load current |
- |
Lamp load |
10 W |
Parallel switching of outputs for redundant control of a load |
not possible |
Parallel switching of outputs for increased power |
not possible |
Actuation of digital input |
|
Switching frequency with resistive load |
max. 1000 Hz |
Switching frequency with inductive load |
max. 0.5 Hz |
Switching frequency on lamp load |
max. 10 Hz |
Internal limitation of inductive shut-off voltage |
L+ (-45 V) |
Short-circuit protection of output |
yes, electronic |
Trigger level |
1 A |
Number of operating cycle of relay outputs |
- |
Switching capacity of contacts |
- |
Output data size |
12 Bit |
Technical data analog inputs |
|
Number of inputs |
2 |
Cable length, shielded |
200 m |
Rated load voltage |
- |
Reverse polarity protection of rated load voltage |
- |
Current consumption from load voltage L+ (without load) |
- |
Voltage inputs |
|
Min. input resistance (voltage range) |
100 k? |
Input voltage ranges |
0 V ... +10 V |
Operational limit of voltage ranges |
+/-3.5% |
Operational limit of voltage ranges with SFU |
- |
Basic error limit voltage ranges |
+/-3.0% |
Ba |