SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus
SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus
SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus

SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus

(Nettó ár: 371.010 Ft)
471.183 Ft
Raktáron
 db 
Cikkszám: 015-CEFNR00

Rövid leírás :

CPU 015N

Powered by SPEED7
SD kártya foglalat reteszeléssel, up tp 64 bővítő modulokkal,
Munkamemória [KB]: 256...512
Integrált Ethernet CP | EtherCAT vezérlő
Interfész [1x RJ45]: EtherCAT-Master
Interfész [1x RJ45]: aktív Ethernet CP, ModbusTCP master/slave, openCommunication
Interfész [2x RJ45]: aktív Ethernet PG/OP kommunikáció DHCP támogatással, switch, ModbusTCP master/slave, openCommunication, I-Device
Interfész [2x RS485]: MPI, PtP: ASCII, STX/ETX, 3964(R), USS master, Modbus master/slave
Opcionális: Integrált mozgásvezérlő 4/8/20 tengely, PROFIBUS master/slave
web szerver 

Programozható SPEED7 Stúdióval, SIMATIC menedzserrel
 


Bővebb információk: :

Yaskawa - VIPA plc
Megosztás   
f t
SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus
SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus
SLIO CPU 015N - 1x EtherCAT master, 1+ 2x Ether. /Modbus TCP ,2x MPI /Modbus

Ismertető :

015-CEFNR00 - CPUs | CPUs STEP7 programmable, EtherCAT

Order no.

015-CEFNR00

TypeCPU 015N
Module ID-

General information

Note-
FeaturesPowered by SPEED7
SD card slot with locking, up tp 64 expansion modules, configurable with SPEED7 Studio, SIMATIC manager
Work memory [KB]: 256...512
Integrated Ethernet CP | EtherCAT controller
Interface [1x RJ45]: EtherCAT-Master
Interface [1x RJ45]: active Ethernet CP, ModbusTCP master/slave, openCommunication
Interface [2x RJ45]: active Ethernet PG/OP-communication with DHCP support, switch, ModbusTCP master/slave, openCommunication, I-Device
Interface [2x RS485]: MPI, PtP: ASCII, STX/ETX, 3964(R), USS master, Modbus master/slave
Optional: Integrated motion controller 4/8/20 axes, PROFIBUS master/slave
Web server

Technical data power supply

Power supply (rated value)DC 24 V
Power supply (permitted range)DC 20.4...28.8 V
Reverse polarity protection
Current consumption (no-load operation)175 mA
Current consumption (rated value)1.1 A
Inrush current3 A
I2t0.1 A2s
Max. current drain at backplane bus3 A
Max. current drain load supply10 A
Power loss8 W

Load and working memory

Load memory, integrated512 KB
Load memory, maximum512 KB
Work memory, integrated256 KB
Work memory, maximal512 KB
Memory divided in 50% program / 50% data
Memory card slotSD/MMC-Card with max. 2 GB

Hardware configuration

Racks, max.5
Modules per rack, max.total max. 64 minus number line extensions
Number of integrated DP master1
Number of DP master via CP-
Operable function modules64
Operable communication modules PtP64
Operable communication modules LAN-

Status information, alarms, diagnostics

Status displayyes
Interruptsno
Process alarmno
Diagnostic interruptno
Diagnostic functionsyes
Diagnostics information read-outpossible
Supply voltage displaygreen LED
Group error displayred SF LED
Channel error displaynone

Command processing times

Bit instructions, min.0.01 µs
Word instruction, min.0.01 µs
Double integer arithmetic, min.0.01 µs
Floating-point arithmetic, min.0.06 µs

Timers/Counters and their retentive characteristics

Number of S7 counters512
S7 counter remanenceadjustable 0 up to 512
S7 counter remanence adjustableC0 .. C7
Number of S7 times512
S7 times remanenceadjustable 0 up to 512
S7 times remanence adjustablenot retentive

Data range and retentive characteristic

Number of flags8192 Byte
Bit memories retentive characteristic adjustableadjustable 0 up to 8192
Bit memories retentive characteristic presetMB0 .. MB15
Number of data blocks4096
Max. data blocks size64 KB
Number range DBs1 ... 8191
Max. local data size per execution level4096 Byte
Max. local data size per block4096 Byte

Blocks

Number of OBs24
Maximum OB size64 KB
Total number DBs, FBs, FCs4096
Number of FBs4096
Maximum FB size64 KB
Number range FBs0 ... 8191
Number of FCs4096
Maximum FC size64 KB
Number range FCs0 ... 8191
Maximum nesting depth per priority class16
Maximum nesting depth additional within an error OB4

Time

Real-time clock buffered
Clock buffered period (min.)30 d
Type of bufferingGoldcap
Load time for 50% buffering period15 min
Load time for 100% buffering period1 h
Accuracy (max. deviation per day)10 s
Number of operating hours counter8
Clock synchronization
Synchronization via MPIMaster/Slave
Synchronization via Ethernet (NTP)Slave

Address areas (I/O)

Input I/O address area2048 Byte
Output I/O address area2048 Byte
Process image adjustable
Input process image preset128 Byte
Output process image preset128 Byte
Input process image maximal2048 Byte
Output process image maximal2048 Byte
Digital inputs16384
Digital outputs16384
Digital inputs central512
Digital outputs central512
Integrated digital inputs-
Integrated digital outputs-
Analog inputs1024
Analog outputs1024
Analog inputs, central512
Analog outputs, central256
Integrated analog inputs-
Integrated analog outputs-

Communication functions

PG/OP channel
Global data communication
Number of GD circuits, max.8
Size of GD packets, max.22 Byte
S7 basic communication
S7 basic communication, user data per job76 Byte
S7 communication
S7 communication as server
S7 communication as client-
S7 communication, user data per job160 Byte
Number of connections, max.32

Functionality Sub-D interfaces

TypeX2
Type of interfaceRS485
ConnectorSub-D, 9-pin, female
Electrically isolated
MPI
MP2I (MPI/RS232)-
DP master-
DP slave-
Point-to-point interface
5V DC Power supplymax. 90mA, isolated
24V DC Power supplymax. 100mA, non-isolated

TypeX3
Type of interfaceRS485
ConnectorSub-D, 9-pin, female
Electrically isolated
MPI
MP2I (MPI/RS232)-
DP masteroptional
DP slaveoptional
Point-to-point interface-
5V DC Power supplymax. 90mA, isolated
24V DC Power supplymax. 100mA, non-isolated

Functionality MPI

Number of connections, max.32
PG/OP channel
Routing
Global data communication
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client-
Transmission speed, min.19.2 kbit/s
Transmission speed, max.12 Mbit/s

Functionality PROFIBUS master

Number of connections, max.32
PG/OP channel
Routing
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client-
Activation/deactivation of DP slaves
Direct data exchange (slave-to-slave communication)-
DPV1
Transmission speed, min.9.6 kbit/s
Transmission speed, max.12 Mbit/s
Number of DP slaves, max.124
Address range inputs, max.2 KB
Address range outputs, max.2 KB
User data inputs per slave, max.244 Byte
User data outputs per slave, max.244 Byte

Functionality PROFIBUS slave

Number of connections, max.32
PG/OP channel
Routing
S7 communication
S7 communication as server
S7 communication as client-
Direct data exchange (slave-to-slave communication)-
DPV1
Transmission speed, min.9.6 kbit/s
Transmission speed, max.12 Mbit/s
Automatic detection of transmission speed-
Transfer memory inputs, max.244 Byte
Transfer memory outputs, max.244 Byte
Address areas, max.32
User data per address area, max.32 Byte

Functionality RJ45 interfaces

TypeX1
Type of interfaceEthernet 10/100 MBit Switch
ConnectorRJ45
Electrically isolated
PG/OP channel
Number of connections, max.4
Productive connections-
Fieldbus-

TypeX5
Type of interfaceEthernet 10/100 MBit Switch
ConnectorRJ45
Electrically isolated
PG/OP channel
Number of connections, max.4
Productive connections-
Fieldbus-

TypeX4
Type of interfaceEthernet 100 MBit
ConnectorRJ45
Electrically isolated
PG/OP channel-
Number of connections, max.-
Productive connections-

TypeX6
Type of interfaceEthernet 10/100 MBit
ConnectorRJ45
Electrically isolated
PG/OP channel
Number of connections, max.8
Productive connections

Point-to-point communication

PtP communication
Interface isolated
RS232 interface-
RS422 interface-
RS485 interface
ConnectorSub-D, 9-pin, female
Transmission speed, min.1200 bit/s
Transmission speed, max.115.5 kbit/s
Cable length, max.500 m

Point-to-point protocol

ASCII protocol
STX/ETX protocol
3964(R) protocol
RK512 protocol-
USS master protocol
Modbus master protocol
Modbus slave protocol
Special protocols-

Properties PROFINET I/O-Controller via PG/OP

Realtime Class-
Conformance Class-
Number of  PN IO devices-
IRT support-
Shared Device supported-
MRP Client supported-
Prioritized start-up-
Number of PN IO lines-
Address range inputs, max.-
Address range outputs, max.-
Transmiting clock-
Update time-
Isochronous mode-
Parallel operation as controller and I-Device-

Properties PROFINET I-Device via PG/OP

I/O Data range, max.512 Byte
Update time1 ms .. 512 ms
Mode as Shared I-Device-

Properties PROFINET I-Device via CP

I/O Data range, max.-
Update time-
Mode as Shared I-Device-

Management & diagnosis via PG/OP

ProtocolsICMP
DCP
LLDP / SNMP
NTP
Web based diagnosis
NCM diagnosis-

Ethernet communication CP

Number of configurable connections, max.8
Number of productive connections by Siemens NetPro, max.8
S7 connectionsBSEND, BRCV, GET, PUT, Connection of active and passive data handling
User data per S7 connection, max.32 KB
TCP-connectionsFETCH PASSIV, WRITE PASSIV, Connection of passive data handling
User data per TCP connection, max.64 KB
ISO-connections-
User data per ISO connection, max.-
ISO on TCP connections (RFC 1006)FETCH PASSIV, WRITE PASSIV, Connection of passive data handling
User data per ISO on TCP connection, max.32 KB
UDP-connections-
User data per UDP connection, max.-
UDP-multicast-connections-
UDP-broadcast-connections-

Ethernet open communication

Number of connections, max.8
ISO on TCP connections (RFC 1006)TSEND, TRCV, TCON, TDISCON
User data per ISO on TCP connection, max.8 KB
TCP-Connections nativeTSEND, TRCV, TCON, TDISCON
User data per native TCP connection, max.8 KB
User data per ad hoc TCP connection, max.1460 Byte
UDP-connectionsTUSEND, TURCV
User data per UDP connection, max.1472 Byte

Ethernet communication via PG/OP

Number of productive connections via PG/OP, max.4
Number of productive connections by Siemens NetPro, max.4
S7 connectionsBSEND, BRCV, GET, PUT, Connection of active and passive data handling
User data per S7 connection, max.64 KB
TCP-connectionsFETCH PASSIV, WRITE PASSIV, Connection of passive data handling
User data per TCP connection, max.8 KB
ISO on TCP connections (RFC 1006)FETCH PASSIV, WRITE PASSIV, Connection of passive data handling
User data per ISO connection, max.8 KB

Ethernet open communication via PG/OP

Number of configurable connections, max.4
ISO on TCP connections (RFC 1006)TSEND, TRCV, TCON, TDISCON
User data per ISO on TCP connection, max.32 KB
TCP-Connections nativeTSEND, TRCV, TCON, TDISCON
User data per native TCP connection, max.32 KB
User data per ad hoc TCP connection, max.1460 Byte
UDP-connectionsTUSEND, TURCV
User data per UDP connection, max.1472 Byte

EtherCAT Master

Number of EtherCAT-slaves128
Update time1 ms .. 512 ms
Address range inputs, max.2 KB
Address range outputs, max.2 KB
EoE support
CoE support
FoE support
Distributed Clock support
Hotconnect Slaves
Isochronous mode

Management & diagnosis

ProtocolsICMP
DCP
Web based diagnosis-
NCM diagnosis-

WebVisu via PG/OP

WebVisu is supported
Max. number of connections WebVisu4
WebVisu supports HTTP
WebVisu supports HTTPS

WebVisu via CP

WebVisu is supported
Max. number of connections WebVisu4
WebVisu supports HTTP
WebVisu supports HTTPS

Housing

MaterialPPE / PPE GF10
MountingProfile rail 35 mm

Mechanical data

Dimensions (WxHxD)131.5 mm x 109 mm x 83 mm
Net weight335 g
Weight including accessories335 g
Gross weight365 g

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certificationyes